Product Features

The VESDA-E VEA series early warning system combines VESDA reliability and early warning with the ability to determine the exact address and a range of notification options that truly surpass traditional machines. Use air sampling points and microbore air sampling points with three alarm sensitivity settings for the sampling points. As a multi-channel addressable system, the VEA detector can divide a protected space into sampling locations, allowing localization of potential fire sources for faster incident response. . The VEA is suitable for protecting areas where precise fire potential is to be determined, thus providing ideal fire detection solutions for health facilities, offices, education, retail, prisons and cabinets. electricity. A range of features that provide flexibility, programming capabilities, enhanced connectivity and reduced total usage costs.

Details

- Standards: UL, ULC

- Determine the exact address with detection superior to the point detector.

- 40 microbore tubes with addresses of separate sampling points.

- Ensure smoke detection with system monitoring from start to finish.

- Business activities are not interrupted by centralized inspection and maintenance.

- Automatic presence of sampling points and rupture detection.

- 3 different sensitivity for each sampling point.

- Capillary tubes with variable length, up to 100m (300ft).

- Detect absolute smoke based on laser

- 2-stage filter and clean air barrier for optical protection.

- Led alarm and error detection.

- 3.5 '' touch screen

- 7 programmable relays.

- 2 GPIs, approved and unattended.

- Event log: 20,000 events.

- iVESDA application to monitor the system on mobile devices.

- IP40 housing

- Ethernet 100 base T.

- Wifi 802.11 b / g / n.

- VESDAnet network, easy cable access.

Product Code

VEA-040-A00, VEA-040-A10

 

Specs

- Supply voltage: 18-30 VDC

 - Suction unit: Linear vacuum suction

 - Operating temperature: Environment: 0 ° C to 39 ° C (32 ° F to 102 ° F)

                                       Sample air: 0 ° C to 50 ° C (32 ° F to 122 ° F)

                                      Test: 0 ° C to 49 ° C (32 ° F to 120 ° F)

- Humidity: 10-95% RH, no dew.

- Microbore tube size: OD: 6 mm, ID 4 mm, OD: 4 mm, ID 2.5 mm

- Microbore tube length: Up to 100m (330 ft)

- IP protection: IP40

- Sensitivity: 0.020% / m (0.006% / ft) - 16% / m (4.88% / ft)

- Fire-1 alarm threshold at Sampling hole: High: (1.6% / m (0.5% / ft)), Enhanced: (4.0% / m (1.3% / ft)), Standard: (8.0% / m (2.5% / ft)).

- Interface: USB (Type 2), Ethernet (RJ45), WiFi (802.11 b / g / n)

- Software features: up to 20,000 events stored in FIFO format, smoke level, user actions, alarms and errors with time and date

Source material

VEA-040-A00, VEA-040-A10

Accessories

Related Products

  • Very sensitive smoke detector VESDA-E-VEP

    VESDA -E-VEP smoke detectors are equipped with the latest and most advanced smoke detectors to provide very early warning and the best counterfeit smoke detector for many applications. Built upon Flair detection technology and years of applied experience, VEP probes get stable operation over their lifetime through absolute calibration. In addition, VEP offers a range of revolutionary features to the value of the user.

  • Very sensitive smoke detector VESDA-E-VEU

    VEU series early warning system is a high-end VESDA-E series detector. Ultra wide sensitivity range; 15 times larger than VESDA VLP and providing more sampling holes and increased coverage in high airflow applications by up to 40%. Significantly longer linear pipes and extended branch network configurations are perfect for high ceiling applications that increase coverage by up to 80% while allowing convenient detector installation for easy warranty. and maintenance. A series of revolutionary new features that provide outstanding detection performance, flexibility, wide programming capabilities, connectivity and reduced total cost during use.

  • Very sensitive smoke detector VESDA-E-VES

    VESDA-E VES is similar to the leading VESDA-E VEP but includes a valve mechanism in the air duct and software to control airflow from four tubes (tubes). This configuration allows a single area to be divided into four distinct areas, for example, distinguishing between separate aisles in a data room. VES allows users to locate smoke sources by identifying the first area that reaches the Warning level. The detector then continues to sample from all areas to monitor the development of the fire and will report individual alarm levels for each area. VES provides four individually configurable alarm levels (Alarm, Action, Fire 1, Fire 2) for each zone for optimal protection. Built on Flair detection technology and years of applied experience, VES detectors achieve stable performance throughout their lifetime through absolute calibration. In addition, VES offers a range of revolutionary features that provide user value.

  • Very sensitive smoke detector for small area 250m2, 500m2 VESDA VLF

    The VESDA VLF-250 detector is a very early warning smoke detector designed to protect small, important business areas of less than 250 m2 or 500 m2.

    The detector works by continuously drawing air into the sampling holes in the pipe network. The air is filtered and fed into the detection chamber where light scattering technology detects the presence of a very small amount of smoke. Detector status information is communicated on the detector screen and via an optional relay or interface card.

    VLF can be installed and put to use without special interfaces or software programming tools. Ultrasonic airflow sensor.