Product Features

Code 885 is a 2-wire normal fixed heat detector. Detector designed for civil projects, factories, commercial buildings to give warnings when a fire occurs. Bring high safety for users.

Details

- Fixed heat detector 885 is a compatible detector with air exhaust RP-2002E.

- The design of the 885 smoke detector is economical and highly sensitive.

- Integrated Led light displays the operating status of the device.

- The terminals (-) IN and (-) OUT are short-circuited inside the detector.

- UL standard

Product Code

885

 

Specs

- Operating temperature: 0-38 degrees C / 32-100 degrees F.

- Relative humidity: 10-93% RH, No dew condensation.

- Operating voltage: 8.5-30 VDC.

- Current in standby mode: ≤ 50µA.

- Current in alarm mode: minimum 2mA, maximum 80mA.

- Maximum air velocity: 20m / s

- Operating sensitivity: 63 degrees C (145.4 degrees F)

Source material

 885

Accessories

Related Products

  • Fixed / Rate of rise heat detector 5601P - System sensor By Honeywell

    Code 5601P is a conventional fixed / Rate of rise heat detector. It is the equipment needed in the fire alarm system for industrial buildings, apartments, commercial ... Brings economic and high safety.

  • Conventional smoke detector 882 - System sensor by Honeywell

    Code 882 is a 2-wire conventional photoelectric smoke detector. Using a modern optical sensor chamber capable of connecting LEDs remotely. The detector is designed for civil works, factories, apartments ... in order to give a warning signal when a fire occurs.

  • Horn Strobes SYS-HS System sensor By Honeywell

    SYS-HS code is a horn device combined with conventional fire flashers. Used for fire alarm systems warning fire fighting for commercial buildings, industrial parks. The fire warning light helps users to quickly recognize the area fire alarm.

  • Alarm Bell SSM24-6 System Sensor by Honeywell

    System Sensor’s SSM and SSV series alarm bells are low current, high decibel notification-appliances for use in fire and burglary systems or other signaling applications.

  • Dual-Action Agent Release Stations, NBG-12LRA Notifier by Honeywell

    NBG-12LRA is one of the indispensable components in the Notifier Agent Release system. The push button activates or stops the exhaust process of the gas extinguishing system. The NBG-12LRA is Agent Release Stations designed for use with NOTIFIER Fire Alarm Control Panels with releasing capabilities and RP Series Releasing Systems.

  • Agent Release Control Panel/ RP-2002E

    The RP-2002 is a six-zone FACP for single and dual hazard agent releasing applications.

    The RP-2002 provides reliable fire detection, signaling and protection for commercial, industrial and institutional buildings requiring agent-based releasing.

    With a compact design, simple activation operations bring high safety for users.